EU 230 V

Integrated system

EU 230 V.

An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW.

INVERTER
Included
ENCLOSURE
IP21
NOMINAL ENERGY
10.24 / 16.076 kWh
AC CONFIGURATION
230 V AC / 50 or 60 Hz
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated AC (kW)
6.2K-10/16KWH-EU10.246.2
6.2K-10/16KWH-EU16.0766.2
12K-16KWH-EU16.07612

6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation.

ModelDimensions (mm)Approx. kg
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H105
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H130
12K-16KWH-EU552 × 254 × 1210 / L × W × H130

Communication: USB / RS485 / dry contact
Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C

Battery storage for tropical homes.

Keep evening essentials and home-office equipment in your backup plan. From an enclosed terrace-house utility room to a protected coastal service space, choose the storage format around your home, its heat and moisture exposure, and the inverter you use.

Temperature:
Charge 0 to 55 °C; discharge −20 to 55 °C
ENCLOSURE
IP21
01

Dry terrace-house utility room

For a new system in a dry enclosed room beside the car porch, one cabinet brings the battery and inverter together and keeps the equipment layout straightforward.

EU 230 V offers integrated battery storage with 6.2 or 12 kW rated AC configurations and an IP21 housing. Allow the model-specific cooling and service space, and select the configuration around your essential circuits.

What is the hottest expected temperature inside this room?
  • Are the vents and service sides clear of parked vehicles, cupboards and stored items?
02

Protected storage for a coastal home

A sheltered equipment space gives coastal homes a place to organise storage and its connections. METMalaysia identifies stronger northeast-monsoon rain exposure in eastern Peninsular Malaysia, western Sarawak and northeastern Sabah.

Compare the compact TR Pro battery and the expandable HP Ultra stack, both listed with IP66 enclosures. Use the room and enclosure together in the design; rain, condensation and coastal exposure still need model-specific review.

Can wind-driven rain, wash water or standing water reach this location?
  • Is the site exposed to coastal air or condensation, and what protection does the exact model require?
03

Existing inverter in a compact service area

Add energy capacity while retaining an existing inverter where compatibility is established. Wall-mounted and modular formats give different ways to use a dedicated service area.

TR Pro is a 51.2 V battery family; HP Ultra is high voltage. Match the inverter's battery-voltage window, CAN/RS485 support and charge/discharge settings. Do not substitute a high-voltage stack for a low-voltage battery connection.

What are the inverter make, model and supported battery-voltage range?
  • Is there room for the battery, mechanical fixing and separate protected power/communication routes?
Specifications
  • TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C. EU 230 V lists charging at 0 to 55 °C and discharging at −20 to 55 °C. Check room temperature and any model-specific derating; do not assume constant output across the entire range.
  • IP66 on TR Pro/HP Ultra is not a blanket approval for any outdoor position. TR standard and HP K list IP20 with IP54 optional, TB rack lists IP20, and EU lists IP21. Verify the exact housing option and installation manual.
  • Use kWh to plan duration and kW to check the load. If air-conditioning or a pump is required, provide its actual running and starting requirements rather than adding it to a basic preset without review.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail.

Original numbered interface map
Original numbered interface mapNumbered map of the AC, battery, PV and communication connections.
AC and battery connection side
AC and battery connection sideAC and battery connection side with cooling fans and the battery breaker.
AC and battery upper detail
AC and battery upper detailUpper AC connection area, cooling fans and BAT terminals.
PV and communication side
PV and communication sidePV and communication side, including the battery communication ports.
PV and communication upper detail
PV and communication upper detailVentilation grille above the PV and communication connection area.

Know your interfaces.

Power connections

AC input / output
The AC connection identified by number 1 in the original map.
AC input breaker
Breaker labelled for the AC input.
BAT+ / BAT-
Positive and negative battery terminals, as labelled in the source.
PV input
Input identified for the PV connection.

Communication

Parallel communication port
Communication connection labelled for parallel operation; configuration availability must be confirmed separately.
Dry contact control
Control interface labelled as dry contact in the brochure.
RS485 / BMS communication port
The communication connection named RS485/BMS in the original label.
Wi-Fi port
Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation.
USB communication port
Communication interface labelled USB.
Battery communication ports
The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs.

Controls & indicators

Battery breaker
Breaker identified for the battery section.

Source: EU 230 V product sheet · PDF page 1