TB rack

Low-voltage battery

TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP20
NOMINAL ENERGY
5.12–16.076 kWh
BATTERY VOLTAGE
51.2 V nominal DC
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated DC (kW)
TB4000X5.125
TB6000X10.2410
TB8000X14.33610
TB8500X16.07610

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

ModelDimensions (mm)Approx. kg
TB4000X482 × 178 × 420 / W × H × D42
TB6000X482 × 223 × 550 / W × H × D78
TB8000X482 × 223 × 710 / W × H × D109.5
TB8500X482 × 223 × 710 / W × H × D112

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

Battery storage for tropical homes.

Keep evening essentials and home-office equipment in your backup plan. From an enclosed terrace-house utility room to a protected coastal service space, choose the storage format around your home, its heat and moisture exposure, and the inverter you use.

Temperature:
Charge 0 to 55 °C; discharge −20 to 60 °C
ENCLOSURE
IP20
01

Dry terrace-house utility room

For a new system in a dry enclosed room beside the car porch, one cabinet brings the battery and inverter together and keeps the equipment layout straightforward.

EU 230 V offers integrated battery storage with 6.2 or 12 kW rated AC configurations and an IP21 housing. Allow the model-specific cooling and service space, and select the configuration around your essential circuits.

What is the hottest expected temperature inside this room?
  • Are the vents and service sides clear of parked vehicles, cupboards and stored items?
02

Protected storage for a coastal home

A sheltered equipment space gives coastal homes a place to organise storage and its connections. METMalaysia identifies stronger northeast-monsoon rain exposure in eastern Peninsular Malaysia, western Sarawak and northeastern Sabah.

Compare the compact TR Pro battery and the expandable HP Ultra stack, both listed with IP66 enclosures. Use the room and enclosure together in the design; rain, condensation and coastal exposure still need model-specific review.

Can wind-driven rain, wash water or standing water reach this location?
  • Is the site exposed to coastal air or condensation, and what protection does the exact model require?
03

Existing inverter in a compact service area

Add energy capacity while retaining an existing inverter where compatibility is established. Wall-mounted and modular formats give different ways to use a dedicated service area.

TR Pro is a 51.2 V battery family; HP Ultra is high voltage. Match the inverter's battery-voltage window, CAN/RS485 support and charge/discharge settings. Do not substitute a high-voltage stack for a low-voltage battery connection.

What are the inverter make, model and supported battery-voltage range?
  • Is there room for the battery, mechanical fixing and separate protected power/communication routes?
Specifications
  • TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C. EU 230 V lists charging at 0 to 55 °C and discharging at −20 to 55 °C. Check room temperature and any model-specific derating; do not assume constant output across the entire range.
  • IP66 on TR Pro/HP Ultra is not a blanket approval for any outdoor position. TR standard and HP K list IP20 with IP54 optional, TB rack lists IP20, and EU lists IP21. Verify the exact housing option and installation manual.
  • Use kWh to plan duration and kW to check the load. If air-conditioning or a pump is required, provide its actual running and starting requirements rather than adding it to a basic preset without review.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

Original front terminal and control strip
Original front terminal and control stripFront terminal and control strip, with the negative terminal left and positive terminal right.
Negative power terminal, front left
Negative power terminal, front leftNegative terminal and minus mark at the front left.
Positive power terminal, front right
Positive power terminal, front rightPositive terminal and plus mark at the front right.
Original communication and control area
Original communication and control areaCommunication connectors, indicators and power switch on the front control strip.
Original cell and BMS construction detail
Original cell and BMS construction detailPartial internal illustration showing battery cells and the BMS board.

Know your interfaces.

Power connections

Positive power terminal
Power port on the viewer's right in the illustrated front panel, with the original plus mark.
Negative power terminal
Power port on the viewer's left in the illustrated front panel, with the original minus mark.

Communication

Dry Connect (source label)
Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.
COM0 / COM1 parallel ports
Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.
CAN / RS485
Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.
RS232
Communication port named RS232; exact pinout and adapter requirements are not provided.

Controls & indicators

Power switch
Power on/off switch as described in the original caption. Operating sequence is not supplied.
SOC / ALM / RUN indicators
Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.
Address identification control
Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

Structure & mounting

Laser welding
The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.
Steel holder
Internal steel holder identified as fixing the cells; not an external connector.
Plastic steel belt (source wording)
Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.
Built-in smart BMS
Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.
Portable handle
Steel handle as described in the source. It is not an electrical port.