A battery is easier to size when the question is specific: which appliances should keep running, and for how long? A list of selected circuits is more useful than a promise of whole-home backup. Use the local examples below as a starting worksheet, then replace every assumption with appliance or installer data.
kWh and kW answer different questions
Energy in kWh describes the amount stored. Power in kW describes how quickly energy is delivered. A larger battery does not automatically provide a higher AC output. Battery-side DC ratings, inverter AC output, starting demand and the backup-circuit arrangement must all support the intended loads.
A local load worksheet
Lights, fans and refrigeration
- Selected LED lighting — 50 W
- Two fans — 120 W combined
- Router — 20 W
- Refrigeration, illustrative cycling average — 110 W
Work-from-home essentials
- Selected lighting — 50 W
- One fan — 60 W
- Router — 20 W
- Laptop and display — 120 W
- Refrigeration, illustrative cycling average — 150 W
Broader selected household circuits
- Selected lighting — 100 W
- Fans — 180 W combined
- Router — 20 W
- Refrigeration, illustrative cycling average — 200 W
- Television — 100 W
- Home-office equipment — 150 W
An indicative runtime, with assumptions visible
For comparison only: runtime in hours = nominal battery energy × assumed usable fraction × assumed conversion efficiency ÷ average load in kW. The example uses 90% usable energy and 90% conversion efficiency as planning assumptions, not product guarantees. Actual runtime also depends on reserve settings, temperature, ageing, standby consumption, duty cycles and the selected inverter.
Illustrative TR6000WX-Pro example
| Assumed load (W) | Indicative runtime (h) |
|---|---|
| 300 | 27.6 |
| 400 | 20.7 |
| 750 | 11.1 |
10.24 kWh nominal energy; assumptions 0.90 × 0.90. This is a calculation, not a tested local household result.
Choose the architecture before the capacity
EU 230 V and TA6000 are integrated battery-and-inverter families. A second standalone inverter is not part of their basic product architecture. TR Pro, TR standard, HP Ultra, HP K and TB are batteries that need a compatible external inverter. Match voltage range, current limits, communication protocol and firmware; nominal voltage alone does not establish compatibility.
Use the backup explorer for a first comparison, then send the selected loads, required duration and existing inverter details with your enquiry. Electrical design and final compatibility need to be confirmed for the actual project.
Questions for your installer
Does IP66 make any outdoor position suitable?
No. IP66 does not by itself establish protection against flooding, condensation or coastal corrosion. Confirm the exact battery version, shelter, mounting, drainage and service clearances with the installer.
Can the basic examples include air-conditioning?
The examples exclude air-conditioning. Provide the appliance's operating load, start-up demand and expected operating time, then confirm both battery energy and inverter output for the proposed system.
Can I add a battery to any existing inverter?
No. Confirm the inverter model, supported battery-voltage range, current limits, communication protocol and settings. A 51.2 V battery and a high-voltage modular stack are different system choices.

